- If multiple receptor stations exist, the "upwind" plumes can be used
to triangulate a source region
- The emission can be estimated if the dispersion from the receptor to source
is assumed to be the same as from source to receptor
- There is additional uncertainty in "backward" dispersion by assuming
a point source at the receptor
- For optimal results dispersion should be during well mixed conditions
srcfwrd_control.txt |    load control file |
srcfwrd_setup.txt |    load setup file |
Forward Calculation
83 09 25 17 |    Run start time |

1.0 |    Emission rate |
1.0 |    Emission duration |

83 09 25 17 00 |    Sampling start time |
1.0 |    Sample averaging time |

S316 41.30 -82.22 |    Grid to Station |
1.0E+15 |    Concentration multiplier |
con2stn_fwd |    Output file name |

Backward Calculation

83 09 26 08 |    Start time |
-15 |    Run duration |

41.30 -82.22 |    Start location |

83 09 26 08 00 |    Sample start time |
83 09 25 17 00 |    Sample stop time |

S001 39.90 -84.22 |    Grid to Station |
con2stn_bak |    Output file name |

|